Ole hyvä ja odota...
Tuote on lisätty ostoskoriin. Näytä ostoskorin sisältö

APC APC Smart-UPS 2200VA LCD RM 2U 230V

Etusivu UPS & Power UPS APC APC Smart-UPS 2200VA LCD RM 2U 230V
Hinnat näkyvät vain verkkokauppaan kirjautuneille käyttäjille.
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)
APC APC Smart-UPS 2200VA LCD RM 2U 230V (SMT2200RMI2U)

APC APC Smart-UPS 2200VA LCD RM 2U 230V

Tuotekoodi:
SMT2200RMI2U
EAN:
0731304284635

APC Smart-UPS 2200 LCD - UPS (telineasennettava) - Vaihtovirta 220/230/240 V - 1.98 kW - 2200 VA - RS-232, USB - lähtöliittimet: 9 - 2U
  • Tuote Ulkoinen UPS
  • Virta 2.2kVA
Kuvaus

APC Smart-UPS 2200VA RM 2U LCD 230V


APC Smart-UPS, 1980 Watts / 2200 VA, Input 230V / Output 230V , Interface Port USB

Includes

CD with software, Documentation CD, Rack mounting hardware, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable

Output

  • Output Power Capacity 1980 Watts / 2200 VA
  • Max Configurable Power 1980 Watts / 2200 VA
  • Nominal Output Voltage 230V
  • Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
  • Efficiency at Full Load 98%
  • Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
  • Waveform Type Sine wave
  • Output Connections (8) IEC 320 C13
  • (1) IEC 320 C19
  • (3) IEC Jumpers

Input

  • Nominal Input Voltage 230V
  • Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
  • Input Connections British BS1363A
  • IEC-320 C20
  • Schuko CEE 7/EU1-16P
  • Cord Length 2 meters
  • Input voltage range for main operations 160 - 286V
  • Input voltage adjustable range for mains operation 151 - 299V
  • Other Input Voltages 220,240

Batteries & Runtime

  • Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time 3 hour(s)
  • Replacement Battery RBC43
  • RBC™ Quantity 1

Communications & Management

  • Interface Port(s) USB
  • Available SmartSlot™ Interface Quantity 1
  • Control panel Multi-function LCD status and control console
  • Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays

Surge Protection and Filtering

  • Surge energy rating 375 Joules

Physical

  • Maximum Height 86.00 mm
  • Maximum Width 480.00 mm
  • Maximum Depth 683.00 mm
  • Net Weight 42.31 KG
  • Shipping Weight 49.73 KG
  • Shipping Height 254.00 mm
  • Shipping Width 600.00 mm
  • Shipping Depth 980.00 mm
  • Units per Pallet 8.00

Environmental

  • Operating Environment 0 - 40 °C
  • Operating Relative Humidity 0 - 95%
  • Operating Elevation 0-3000 meters
  • Storage Temperature -15 - 45 °C
  • Storage Relative Humidity 0 - 95%
  • Storage Elevation 0-15000 meters
  • Audible noise at 1 meter from surface of unit 55.00 dBA
  • Online Thermal Dissipation 215.00 BTU/hr

Conformance

  • Regulatory Approvals C-tick,CE,EN 60950,EN/IEC 62040-1-1,EN/IEC 62040-2,GOST,GS Mark,IRAM,VDE,WEEE
  • Standard Warranty 3 years repair or replace (excluding battery) and 2 year for battery
  • Environmental Compliance RoHS 7b Exemption,REACH: Contains No SVHCs

Features

Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Provides actual kilowatt hours of usage for energy conscious users.

Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).

Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

Enables centralized management via StruxureWare Central.

Reduces utlility costs, generates less heat.

Customize UPS capabilities with management cards.

Provides temporary battery power when the utility power is out.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Features & Benefits

Availability

Gives higher application availability by correcting low and high voltage conditions without using the battery.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Automatically starts up the connected equipment upon the return of utility power.

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Warns when a battery is not available to provide backup power.

Manageability

Provides remote management of the UPS over the network.

Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

Quickly understand unit and power status with visual indicators.

Provides management of the UPS via a serial port.

Provides management of the UPS via a USB port (not available on all models).

Warns when a battery is not available to provide backup power.

Serviceability

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Provides early-warning fault analysis ensuring proactive component replacement.

Enables a quick recovery from overload events.

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Adaptability

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Safety

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Huomioi, että kuva on suuntaa-antava ja varsinainen tuote saattaa ulkoasultaan poiketa tuotekuvasta (esim. tietokoneisiin ei välttämättä sisälly näyttöä, vaikka kuvassa sellainen olisikin). Jos tuotenimikkeessä on eri tiedot kuin tuotekuvauksessa, tuotenimikkeen tieto on oikein. Jos jokin asia jää epäselväksi, lähetä sähköpostia tukeen ennen tuotteen tilaamista.